Emergency lighting in London

Lumina Fire & Security installs, tests and repairs emergency lighting across London for blocks of flats, offices, shops and public buildings. We are based in Kent, and we design and test systems in line with BS 5266-1, upgrade old fittings to LED and keep your escape routes lit when the mains fails.

  • BS 5266-1What designs and tests follow
  • LEDUpgrades for older fittings
  • 3-hourAnnual duration test carried out

Monthly flick tests and the annual duration test

BS 5266-1 calls for a short functional test every month, often called a flick test, where the mains supply to the fittings is cut briefly to check each one switches to battery. Once a year, a full duration test runs the system on battery for its rated time, usually three hours, to prove the batteries still hold their charge. Results from both should go in the emergency lighting logbook. Fittings that fail are repaired or have their batteries replaced.

  • Monthly flick test of every fitting
  • Annual full rated duration test
  • Results recorded in the logbook
  • Failed fittings repaired or batteries replaced

Maintained or non-maintained, self-contained or central battery

Maintained fittings stay lit all the time and keep working on battery during a power cut, which suits places like cinemas, theatres and some exit signs. Non-maintained fittings only light up when the mains fails, which is common in offices and blocks of flats. Most buildings use self-contained fittings, each with its own battery. Larger sites sometimes use a central battery system, which keeps batteries in one place for easier testing but needs fire-resistant cabling to each fitting.

  • Maintained fittings where lights must always be on
  • Non-maintained fittings for most offices and flats
  • Self-contained units for small and medium buildings
  • Central battery systems for larger sites

Stairwells, basements and LED upgrades in London buildings

Communal stairwells in London blocks of flats, many with no windows on some landings, need reliable lighting to get residents out in a power cut. Basement offices, gyms, bars and storage areas, common across central London, have no daylight at all, so emergency lighting is essential there. Many older buildings still have fluorescent bulkheads with failing batteries. Replacing them with LED fittings, some with self-test features, can reduce failures and make routine testing easier.

  • Stairwells and landings in blocks of flats
  • Basements and rooms with no natural light
  • Exit signs over final exits and route changes
  • LED replacements for ageing fluorescent fittings

How the job works

  1. 1Map escape routes and dark areasWe walk the escape routes, stairs, exits and windowless rooms to see where emergency lighting and signs are needed.
  2. 2Plan fittings and system typeYou receive a layout showing fitting types, positions and whether maintained, non-maintained or central battery is proposed.
  3. 3Install and wire into circuitsFittings and signs are installed and wired so they can be tested, with a key switch or test facility provided.
  4. 4Run the first duration testThe system is run on battery for its full rated time, results are recorded, and the logbook and certificate are handed over.

What you get from Lumina in London

  • Emergency lighting designed, installed and tested by the same contractor that can maintain it afterwards.
  • Logbook and test certificates provided so you have a record of every monthly and annual test.
  • Emergency lighting, fire alarms and fire doors can be checked together for blocks and commercial buildings.

Common questions

Can we do the monthly emergency lighting test ourselves?

Yes. A responsible person on site can do the monthly flick test, as long as they know how to operate the test switch safely and record the results. Many buildings leave the annual duration test to a contractor, because it takes longer and needs the area to be safe during the recharge period afterwards.

How long does the building stay unprotected after a duration test?

After a full duration test, batteries need time to recharge, often around 24 hours. During that time the emergency lighting may not last its full rated duration if the mains fails. That is why annual tests are usually done when the building is quiet, or tested in sections so not all fittings are discharged at once.

Are self-testing LED emergency lights worth it?

Self-test fittings run their own monthly and annual tests and show a status light if they fail. They reduce the time spent on manual testing and make faults easier to spot. Someone still needs to check the indicators and keep records. They suit larger buildings and sites where manual testing is hard to organise.

Get in touch

Talk to us about Emergency Lighting in London.

Free, no-obligation surveys and quotes for commercial, public and residential properties. Call us or drop us an email and we will get straight back to you.