
Fire Safety
Fire Extinguisher Servicing & Supply from Kent, across the South East
We assess the risks on your premises, supply the correct extinguisher types and carry out annual servicing so they are ready to use.
Fire Extinguishers for commercial, public and residential buildings
The right extinguishers, in the right places, serviced every year. Lumina Fire & Security, Kent-based, provides fire extinguishers work across the South East.
What is included
- Fire risk based equipment selection
- Supply, mounting and signage
- Annual servicing and discharge testing
- Replacement and refills
Fire extinguisher types and fire classes
Fires are grouped into classes by what is burning, and each extinguisher type is suited to some classes and dangerous on others. Class A covers solids such as paper, wood and textiles, Class B flammable liquids, Class C flammable gases and Class F cooking oils and fats. Electrical equipment is not a class of its own, but it needs an extinguisher that does not conduct electricity, usually CO2.
- Water and foam for Class A, with foam also covering Class B
- CO2 for electrical equipment and small liquid fires
- Dry powder for gases and mixed risks, mainly outdoors or in plant areas
- Wet chemical for Class F fires in commercial kitchens
BS 5306-3 servicing and extended service
BS 5306-3 is the code of practice for servicing portable extinguishers. Every extinguisher should get a basic service by a competent person at least once a year, checking its condition, pressure, weight, seals and signage. At longer intervals, usually every five years for water, foam, powder and wet chemical, an extended service discharges and recharges the unit, while CO2 extinguishers are overhauled or replaced at ten years.
- Annual basic service with a dated service label
- Extended service or discharge test at the set interval
- Damaged, out-of-date or discharged units replaced
- Service report listing every extinguisher and location
How many fire extinguishers you need and where they go
BS 5306-8 gives guidance on selecting and positioning extinguishers, based on floor area, the fire risks present and how far people have to walk to reach one. As a general guide, nobody should need to travel more than 30 metres to a Class A extinguisher, and most floors need at least two. Extinguishers are best sited on escape routes and near exits, so people move towards safety when collecting one.
- Numbers based on floor area and the risks on each floor
- Grouped at fire points near exits and on landings
- Specialist units placed beside kitchens and plant rooms
- Wall brackets or stands with clear identification signs
Who needs fire extinguishers, and who is responsible for them?
The Fire Safety Order requires the responsible person for non-domestic premises to provide appropriate fire-fighting equipment where it is needed, based on the fire risk assessment. For most workplaces, shops, schools and community buildings that includes portable extinguishers, while landlords of blocks and HMOs should follow what the assessment for their building says. The responsible person must also make sure the equipment is maintained and that people who may need to use it know how. Where a building has several occupiers, it helps to agree in writing who looks after the extinguishers in shared areas.
- Employers and business owners in their own premises
- Landlords and managing agents for common areas
- Equipment matched to the fire risk assessment
- Clear responsibility where buildings have several occupiers
Common problems found on extinguisher service visits
Many extinguisher problems are about where and how units are kept rather than the extinguishers themselves. Units turn up on the floor instead of their brackets, moved away from their fire point, used as door stops or hidden behind stock. Others have lost pressure, have damaged hoses, missing safety pins or broken tamper seals, or have been partly discharged and put back. Extinguishers bought online and hung by staff have often never been commissioned on site, which BS 5306-3 expects for every new unit. Each issue is noted in the service report and put right or quoted for.
- Units moved, blocked or used to prop doors open
- Low pressure, damaged hoses or missing safety pins
- Partly used extinguishers put back on the wall
- New units never commissioned by a competent person
How the job works
- 1Walk each floor with the risk assessmentWe go floor by floor with your fire risk assessment, noting the hazards in each area, the escape routes and where fire points would be easiest to reach.
- 2Propose types and fire point positionsYou receive a simple plan showing which extinguisher types are proposed, how many, and where each one will be mounted, before any equipment is supplied.
- 3Commission, mount and sign each unitNew extinguishers are commissioned on site, fixed on brackets or stands at a suitable height, and given clear signs showing which fires each type is for.
- 4Set up the annual service registerEach unit is added to a register with its location and key dates, so the next annual service and any extended service can be planned well ahead.

Fire Extinguishers near you
Local pages with details for the areas we cover most, plus every county and city we work in.
Official guidance
Last reviewed: November 2026
Fire Extinguishers: common questions
Can staff use any fire extinguisher on any fire?
No. Using the wrong type can make a fire worse or put the user at risk, such as water on a fat fire or on live electrics. Each extinguisher has a coloured band and a label showing the fire classes it is safe for, and signs beside it explain its use. Basic training helps staff choose correctly and know when to leave instead.
What happens to an extinguisher that fails its service?
If an extinguisher is damaged, has lost pressure, is past its service life or has been partly used, it is taken out of service and either refilled or replaced. We tell you why it failed and leave a working unit in place where possible, so the area is not left without cover. Old units are taken away for recycling.
Do blocks of flats need fire extinguishers in the common parts?
Not always. In many purpose-built blocks, fire safety guidance advises against extinguishers in common corridors, as residents should leave rather than tackle a fire. They may still be needed in plant rooms, bin stores or areas used by staff. The fire risk assessment for the building should state what is required, and we supply to that.
Is a fire blanket a replacement for a kitchen extinguisher?
A fire blanket is useful for small pan fires and burning clothing, and is common in staff kitchens. It is not a substitute for a wet chemical extinguisher where there are commercial deep fat fryers or large cooking ranges. We look at the cooking equipment on site and recommend the combination that suits it.
Related services
Fire Risk Assessments
A written assessment of the fire risks in your building, with a clear, prioritised list of what to do about them.
Fire Alarm Installation
Conventional, addressable and wireless fire alarm systems designed around your building.
Fire Alarm Servicing
Scheduled maintenance visits and certification to keep your system reliable and compliant.
Get in touch
Talk to an engineer about your building.
Free, no-obligation surveys and quotes for commercial, public and residential properties. Call us or drop us an email and we will get straight back to you.