Skip to content
Lumina Fire & Security

Extinguishers · London

Fire extinguisher servicing in London

Lumina Fire & Security provides fire extinguisher servicing across London for restaurants, shops, offices, schools and residential buildings. We are a Kent-based contractor, and we service extinguishers every year, carry out extended servicing and discharge tests when they fall due, and supply the right types for each risk.

  • AnnualBasic service on every extinguisher
  • Risk-basedTypes chosen for each area
  • Supply + fitMounting and signage included

Annual and extended servicing intervals

BS 5306-3 sets out a basic service for portable extinguishers at least once a year, covering weight or pressure, seals, hose, signage and position. On top of that, typical guidance calls for an extended service or discharge test about every five years for water, foam and powder extinguishers, and an overhaul or pressure test about every ten years for CO2. Units that are damaged, corroded or past their usable life are replaced rather than serviced.

  • Basic service on every unit once a year
  • Extended service on water, foam and powder around five-yearly
  • CO2 overhaul or pressure test around ten-yearly
  • Damaged or obsolete units replaced

Choosing the right extinguisher for the risk

Different fires need different extinguishers, and the wrong one can make things worse. Commercial kitchens need a wet chemical Class F extinguisher for cooking oil and fat. Server rooms and areas with electrical equipment are usually covered by CO2. Offices and corridors are typically protected with water or foam for paper, furniture and fittings. Powder extinguishers are generally avoided indoors where possible, because the discharge reduces visibility and is hard to clean up.

  • Wet chemical Class F for commercial kitchens
  • CO2 for server rooms and electrical risks
  • Water or foam for offices and general areas
  • Fire blankets where small cooking fires are likely

Restaurants, retail and mounting in London premises

London’s restaurants, takeaways and cafes, from busy high streets to areas like Soho and Shoreditch, rely on correct kitchen extinguishers and staff who know which one to use. Shops and small retail units often have tight floor space, so extinguishers need to be wall-mounted or on stands near exits where they will not be blocked by stock. Each point should have clear signage showing the type and the fires it is suitable for.

  • Extinguishers mounted near exits and on escape routes
  • Stands used where walls are not suitable
  • ID signs showing type and fire class
  • Positions kept clear of stock and furniture

How the job works

  1. 1List every extinguisher on siteWe record each unit’s type, location, manufacture date and condition, building a register for future visits.
  2. 2Service and tag each unitEvery extinguisher gets its basic service and a dated label, with extended servicing done where it is due.
  3. 3Check the mix against the risksWe compare what you have with the hazards in each area and recommend changes where the type or position is wrong.
  4. 4Report, replace and top upYou get a service report, and replacements, refills or new signage are supplied and fitted once approved.

What you get from Lumina in London

  • A clear register of every extinguisher, its location and service history, ready for your fire risk assessor.
  • Advice on extinguisher types based on what actually happens in each room, not a standard kit for every building.
  • Extinguisher servicing can be booked alongside fire alarm and emergency lighting maintenance.

Official guidance

Last reviewed: November 2026

Common questions

What extinguishers does a London restaurant kitchen need?

Most commercial kitchens need a wet chemical Class F extinguisher for cooking oil and fat fires, often with a fire blanket and a CO2 extinguisher for electrical equipment. The exact mix depends on the size of the kitchen, the fryers and ranges in use, and your fire risk assessment. Staff should also know which extinguisher to use on which fire.

What is a discharge test on a fire extinguisher?

A discharge test involves fully discharging the extinguisher to check it works, then inspecting the internals, refilling and recharging it, or replacing it. It is part of extended servicing and typically falls due around every five years for water, foam and powder units. The engineer will tell you which units are due.

Can we replace extinguishers rather than service them?

Sometimes replacing an old extinguisher costs about the same as an extended service or refill, so it can make sense. Damaged, corroded or obsolete units should be replaced anyway. New extinguishers still need their annual service, so a maintenance schedule remains necessary.

Get in touch

Talk to us about Fire Extinguishers in London.

Free, no-obligation surveys and quotes for commercial, public and residential properties. Call us or drop us an email and we will get straight back to you.