Emergency Lighting Installation & Repairs from Kent, across the South East
When the power fails, emergency lighting guides people out. We install new systems, upgrade older fittings and repair faults so your escape routes stay lit.
Emergency Lighting for commercial, public and residential buildings
Escape route and exit lighting installed, tested and repaired to keep routes visible. Lumina Fire & Security, Kent-based, provides emergency lighting work across the South East.
What is included
- Maintained and non-maintained fittings
- Illuminated exit signage
- Duration testing and certification
- Repairs and battery replacement
Where emergency lighting is needed under BS 5266-1
BS 5266-1 is the code of practice for emergency lighting in non-domestic buildings and the common parts of residential blocks. It covers escape route lighting, open area lighting in larger spaces and lighting for high-risk tasks that need to be shut down safely. Fittings are placed at points of particular danger, such as changes of direction, stairs and exits, as well as near fire alarm call points and fire-fighting equipment.
- Every exit door and along each escape route
- Stairs, changes of level and changes of direction
- Near call points, extinguishers and first aid points
- Plant rooms, lift cars and larger toilets
Monthly and annual emergency lighting tests
Each fitting should get a short functional test every month, simulating a mains failure to check that it lights from its battery. Once a year a full rated duration test is carried out, usually three hours, to prove the batteries will last as long as the design requires. Results go in the emergency lighting logbook, along with any failures and the date they were put right.
- Monthly brief test of every fitting and exit sign
- Annual full duration test with time to recharge afterwards
- Logbook entries for tests, faults and repairs
- Self-test fittings can automate testing but still need checking
LED upgrades and emergency lighting repairs
Older fluorescent emergency fittings use more power, need more tube and battery changes, and are increasingly hard to get parts for. Replacing them with LED fittings usually lowers maintenance and lets you add self-test features at the same time. Where only part of a system has failed, repairs such as replacing batteries, control gear or damaged diffusers are often enough.
- Failed batteries replaced in existing fittings
- Fluorescent fittings swapped for LED equivalents
- Exit signs updated to the current pictogram format
- Key switches added so testing does not cut the main lights
How much light emergency lighting needs to give
Emergency lighting is designed to minimum light levels set out in BS EN 1838 and applied through BS 5266-1. Escape routes up to two metres wide need at least 1 lux along the centre line, larger open areas need at least 0.5 lux across the floor, and high-risk task areas need a higher level so work can be made safe before people leave. Reaching those figures depends on each fitting’s output, mounting height and spacing, so a layout worked out from manufacturer data is more reliable than placing a light by each door and hoping it is enough.
- At least 1 lux on the centre line of escape routes
- 0.5 lux across open areas, excluding a narrow border at the walls
- Higher levels where hazardous processes must be shut down
- Layouts checked against each fitting’s photometric data
What you receive when emergency lighting is installed
A new or extended emergency lighting system should be handed over with the paperwork the responsible person needs to keep it in order. BS 5266-1 sets out what is expected, including a completion certificate covering design, installation and verification, and a logbook for recording routine tests and faults. As-fitted drawings showing each fitting and exit sign make monthly testing quicker and help anyone reviewing the building, such as a fire risk assessor, see what is installed. We also explain how the test facility works, whether that is a key switch, self-test indicators or a central test panel.
- Completion certificate covering design, installation and verification
- Logbook ready for monthly and annual test entries
- As-fitted drawings marking every fitting and sign
- A walk-through of test switches and indicators
How the job works
- 1Record what is already installedExisting fittings, signs and circuits are recorded, with battery age, fitting type and any gaps in coverage noted against BS 5266-1 before anything new is proposed.
- 2Calculate coverage from photometric dataFitting positions are worked out using manufacturer light output data, so escape routes, open areas and stairs reach the required levels without unnecessary fittings.
- 3Fit, connect and label the test pointsFittings and exit signs are installed on the correct unswitched supply, and test key switches are fitted and labelled so monthly checks are quick for staff.
- 4Verify on battery and certifyWith the mains supply isolated, every fitting is checked for operation and duration, then the certificate, drawings and logbook are issued for your fire safety records.

Emergency Lighting near you
Local pages with details for the areas we cover most, plus every county and city we work in.
Official guidance
Last reviewed: November 2026
Emergency Lighting: common questions
What is the difference between maintained and non-maintained emergency lighting?
A maintained fitting is on all the time the building is occupied and stays lit from its battery when the power fails, which suits places like cinemas, halls and exit signs in public areas. A non-maintained fitting only comes on when the normal lighting fails. Your fire risk assessment and how the building is used decide which you need in each area.
Why did some emergency lights fail their annual duration test?
The most common reason is battery ageing. Emergency batteries typically need replacing every few years, and a battery that still works on a short monthly test may not last the full three hours. Faulty charging circuits, damaged wiring and fittings left without power after alterations are other causes. We record the failures and quote for the repairs needed.
Can emergency lighting tests be done while the building is in use?
Monthly tests take a few seconds per fitting and can be done during the working day. The annual duration test drains the batteries, so the lights will not be ready for a real power cut for some hours afterwards. It is best done at the end of the day or when the building is quiet, or in sections so part of the building stays covered.
Do we need emergency lighting in a small shop or office?
Most workplaces need some emergency lighting, but how much depends on the layout, whether there is enough borrowed light from outside, and how easily people can find the exit. A small single room with an obvious exit may need very little. Your fire risk assessment should say what is required, and we can survey the premises against BS 5266-1.
Related services
Fire Risk Assessments
A written assessment of the fire risks in your building, with a clear, prioritised list of what to do about them.
Fire Alarm Installation
Conventional, addressable and wireless fire alarm systems designed around your building.